{"product_id":"manual-gate-valve-3-1-16-15m-fc-style-ee-0-5-trim","title":"MANUAL GATE VALVE, 3-1\/16\", 15M, FC-STYLE, EE-0.5 TRIM","description":"\u003ch2 data-start=\"1513\" data-end=\"1530\"\u003e\u003cstrong data-start=\"1516\" data-end=\"1528\"\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1531\" data-end=\"1952\"\u003eThe Blaze Manual Gate Valve, 3-1\/16\", 15,000 PSI (15M), FC-Style, is engineered for reliable high-pressure shutoff in the most demanding upstream applications. Manufactured to API 6A requirements and constructed from forged alloy steel, this valve provides consistent isolation performance in wellhead systems, choke and kill manifolds, frac support equipment, drilling manifolds, and high-pressure production operations.\u003c\/p\u003e\n\u003cp data-start=\"1954\" data-end=\"2350\"\u003eThe FC-Style design supports stable gate movement and dependable sealing performance under high-pressure conditions, while the corrosion-resistant trim option is suitable for standard service media such as hydrocarbons, drilling mud, completion fluids, and high-density wellsite fluids. Manual handwheel operation enables controlled actuation where hydraulic or electric systems are not required.\u003c\/p\u003e\n\u003cp data-start=\"2352\" data-end=\"2540\"\u003eBuilt for harsh field environments, the Blaze 3-1\/16\" 15M Manual Gate Valve offers rugged construction, service-friendly access, and reliable performance across continuous pressure cycles.\u003c\/p\u003e\n\u003chr data-start=\"2542\" data-end=\"2545\"\u003e\n\u003ch2 data-start=\"2547\" data-end=\"2572\"\u003e\u003cstrong data-start=\"2549\" data-end=\"2572\"\u003eFeatures \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2574\" data-end=\"3285\"\u003e\n\u003cli data-start=\"2574\" data-end=\"2667\"\u003e\n\u003cp data-start=\"2576\" data-end=\"2667\"\u003e\u003cstrong data-start=\"2576\" data-end=\"2597\"\u003eAPI 6A Compliant:\u003c\/strong\u003e Manufactured to recognized wellhead and pressure-control standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2668\" data-end=\"2756\"\u003e\n\u003cp data-start=\"2670\" data-end=\"2756\"\u003e\u003cstrong data-start=\"2670\" data-end=\"2698\"\u003e15,000 PSI Rating (15M):\u003c\/strong\u003e Suitable for extreme high-pressure upstream operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2757\" data-end=\"2843\"\u003e\n\u003cp data-start=\"2759\" data-end=\"2843\"\u003e\u003cstrong data-start=\"2759\" data-end=\"2777\"\u003eFC-Style Body:\u003c\/strong\u003e Supports stable gate travel and consistent sealing performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2844\" data-end=\"2919\"\u003e\n\u003cp data-start=\"2846\" data-end=\"2919\"\u003e\u003cstrong data-start=\"2846\" data-end=\"2875\"\u003eCorrosion-Resistant Trim:\u003c\/strong\u003e Designed for standard service durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2920\" data-end=\"3001\"\u003e\n\u003cp data-start=\"2922\" data-end=\"3001\"\u003e\u003cstrong data-start=\"2922\" data-end=\"2943\"\u003eReliable Shutoff:\u003c\/strong\u003e Provides dependable isolation in critical applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3002\" data-end=\"3096\"\u003e\n\u003cp data-start=\"3004\" data-end=\"3096\"\u003e\u003cstrong data-start=\"3004\" data-end=\"3032\"\u003eForged Alloy Steel Body:\u003c\/strong\u003e Built to withstand abrasive fluids and high-pressure cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3097\" data-end=\"3193\"\u003e\n\u003cp data-start=\"3099\" data-end=\"3193\"\u003e\u003cstrong data-start=\"3099\" data-end=\"3130\"\u003eManual Handwheel Operation:\u003c\/strong\u003e Enables direct, controlled actuation without external power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3285\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3285\"\u003e\u003cstrong data-start=\"3196\" data-end=\"3224\"\u003eService-Friendly Design:\u003c\/strong\u003e Facilitates inspection, maintenance, and part replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3287\" data-end=\"3290\"\u003e\n\u003ch2 data-start=\"3292\" data-end=\"3332\"\u003e\u003cstrong data-start=\"3294\" data-end=\"3332\"\u003eSpecifications \u0026amp; Technical Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"3334\" data-end=\"3370\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3370\"\u003eDetailed Specification Table\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3372\" data-end=\"4106\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3372\" data-end=\"3408\"\u003e\n\u003ctr data-start=\"3372\" data-end=\"3408\"\u003e\n\u003cth data-start=\"3372\" data-end=\"3387\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3374\" data-end=\"3386\"\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"3387\" data-end=\"3408\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3389\" data-end=\"3406\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3446\" data-end=\"4106\"\u003e\n\u003ctr data-start=\"3446\" data-end=\"3484\"\u003e\n\u003ctd data-start=\"3446\" data-end=\"3463\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3448\" data-end=\"3462\"\u003eValve Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3463\" data-end=\"3484\" data-col-size=\"md\"\u003eManual Gate Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3485\" data-end=\"3507\"\u003e\n\u003ctd data-start=\"3485\" data-end=\"3496\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3487\" data-end=\"3495\"\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3496\" data-end=\"3507\"\u003e3-1\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3508\" data-end=\"3550\"\u003e\n\u003ctd data-start=\"3508\" data-end=\"3530\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3510\" data-end=\"3529\"\u003ePressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3530\" data-end=\"3550\"\u003e15,000 PSI (15M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3551\" data-end=\"3582\"\u003e\n\u003ctd data-start=\"3551\" data-end=\"3570\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3553\" data-end=\"3569\"\u003eDesign Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3570\" data-end=\"3582\" data-col-size=\"md\"\u003eFC-Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3583\" data-end=\"3650\"\u003e\n\u003ctd data-start=\"3583\" data-end=\"3603\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3585\" data-end=\"3602\"\u003eTrim Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3603\" data-end=\"3650\"\u003eCorrosion-Resistant Trim (Standard Service)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3651\" data-end=\"3680\"\u003e\n\u003ctd data-start=\"3651\" data-end=\"3670\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3669\"\u003eAPI Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3670\" data-end=\"3680\"\u003eAPI 6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3681\" data-end=\"3723\"\u003e\n\u003ctd data-start=\"3681\" data-end=\"3701\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3683\" data-end=\"3700\"\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3701\" data-end=\"3723\"\u003eForged Alloy Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3724\" data-end=\"3769\"\u003e\n\u003ctd data-start=\"3724\" data-end=\"3747\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3726\" data-end=\"3746\"\u003eOperation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3747\" data-end=\"3769\"\u003eManual (Handwheel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3770\" data-end=\"3818\"\u003e\n\u003ctd data-start=\"3770\" data-end=\"3789\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3772\" data-end=\"3788\"\u003eService Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3789\" data-end=\"3818\" data-col-size=\"md\"\u003eStandard Oilfield Service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3819\" data-end=\"3885\"\u003e\n\u003ctd data-start=\"3819\" data-end=\"3841\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3821\" data-end=\"3840\"\u003eEnd Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3841\" data-end=\"3885\" data-col-size=\"md\"\u003eFlanged (other configurations available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3886\" data-end=\"3967\"\u003e\n\u003ctd data-start=\"3886\" data-end=\"3913\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3888\" data-end=\"3912\"\u003eTypical Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3913\" data-end=\"3967\" data-col-size=\"md\"\u003eWellhead, frac, choke \u0026amp; kill, drilling, production\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3968\" data-end=\"4024\"\u003e\n\u003ctd data-start=\"3968\" data-end=\"3993\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3970\" data-end=\"3992\"\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3993\" data-end=\"4024\" data-col-size=\"md\"\u003eBased on selected materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4025\" data-end=\"4106\"\u003e\n\u003ctd data-start=\"4025\" data-end=\"4052\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4027\" data-end=\"4051\"\u003eTesting \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4052\" data-end=\"4106\"\u003eHydrostatic, functional testing, NDT, traceability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4108\" data-end=\"4111\"\u003e\n\u003ch2 data-start=\"4113\" data-end=\"4131\"\u003e\u003cstrong data-start=\"4115\" data-end=\"4131\"\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4133\" data-end=\"4187\"\u003eSuitable for extreme high-pressure operations such as:\u003c\/p\u003e\n\u003cul data-start=\"4189\" data-end=\"4393\"\u003e\n\u003cli data-start=\"4189\" data-end=\"4223\"\u003e\n\u003cp data-start=\"4191\" data-end=\"4223\"\u003eHigh-pressure wellhead systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4224\" data-end=\"4250\"\u003e\n\u003cp data-start=\"4226\" data-end=\"4250\"\u003eChoke \u0026amp; kill manifolds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4251\" data-end=\"4285\"\u003e\n\u003cp data-start=\"4253\" data-end=\"4285\"\u003eFrac and stimulation equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4286\" data-end=\"4322\"\u003e\n\u003cp data-start=\"4288\" data-end=\"4322\"\u003eDrilling choke and mud manifolds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4323\" data-end=\"4347\"\u003e\n\u003cp data-start=\"4325\" data-end=\"4347\"\u003eProduction flowlines\u003c\/p\u003e\n\u003cul data-start=\"4189\" data-end=\"4393\"\u003e\n\u003cli data-start=\"4348\" data-end=\"4393\"\u003e\n\u003cp data-start=\"4350\" data-end=\"4393\"\u003eCompletion \u0026amp; intervention support systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4395\" data-end=\"4479\"\u003eDesigned for reliable isolation in systems handling abrasive or high-density fluids.\u003c\/p\u003e\n\u003chr data-start=\"4481\" data-end=\"4484\"\u003e\n\u003ch2 data-start=\"4486\" data-end=\"4509\"\u003e\u003cstrong data-start=\"4488\" data-end=\"4509\"\u003eQuality Assurance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4511\" data-end=\"4741\"\u003eEach valve is produced under API 6A and API Q1 quality systems and undergoes hydrostatic pressure testing, functional actuation checks, NDT inspection, and material traceability verification to ensure consistent field reliability.\u003c\/p\u003e\n\u003chr data-start=\"4743\" data-end=\"4746\"\u003e\n\u003ch2 data-start=\"4748\" data-end=\"4771\"\u003e\u003cstrong data-start=\"4750\" data-end=\"4769\"\u003eRequest a Quote\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4772\" data-end=\"4813\"\u003e📞 +1 405 666 5011\u003cbr data-start=\"4790\" data-end=\"4793\"\u003e📧 \u003ca data-start=\"4796\" data-end=\"4811\" class=\"decorated-link cursor-pointer\" rel=\"noopener\"\u003eseo@blazess.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Blaze Sales \u0026 Service","offers":[{"title":"Default Title","offer_id":47304842084597,"sku":null,"price":6750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/5785\/1637\/files\/Manual_FC_GATE_VALVE-_API_6A.png?v=1772652114","url":"https:\/\/blazess.com\/de\/products\/manual-gate-valve-3-1-16-15m-fc-style-ee-0-5-trim","provider":"Blaze Sales \u0026 Service","version":"1.0","type":"link"}