{"product_id":"9-16-hp-male-x-1-2-npt-female-adapter-10-000-psi-stainless-steel-crossover-fitting","title":"9\/16\" HP Male x 1\/2\" NPT Female Adapter – 10,000 PSI Stainless Steel Crossover Fitting","description":"\u003cp data-path-to-node=\"4\"\u003eThe 9\/16\" High-Pressure (HP) Male x 1\/2\" NPT Female Adapter is a robust crossover fitting engineered to seamlessly connect ultra-high-pressure coned and threaded tubing systems to standard, larger-bore pipe thread instrumentation. Rated for a Maximum Allowable Working Pressure (MAWP) of 10,000 PSI (10K)—the standard safe operational limit for a 1\/2\" NPT connection—this adapter allows operators to safely transition between rigid high-pressure manifolds and widely available tapered-thread equipment.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003eOne end features a precision-machined 9\/16\" High-Pressure (HP) Male connection, utilizing the industry-standard Autoclave-style coned and threaded design to provide a blowout-proof, bubble-tight metal-to-metal seal. The opposing end features a robust 1\/2\" National Pipe Thread (NPT) Female port, designed to accept larger instrumentation such as heavy-duty pressure gauges, pulsation dampeners, and high-volume bleed valves. By providing a direct transition, this single-piece fitting eliminates the need for multi-component thread bushings, significantly reducing potential leak paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003eManufactured from premium cold-worked 316 stainless steel, this adapter delivers exceptional tensile strength and superior resistance to corrosive fluids, harsh offshore environments, and mechanical fatigue, ensuring reliable fluid containment and system integrity.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eFeatures \u0026amp; Benefits\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e10,000 PSI MAWP Rating:\u003c\/b\u003e Safely contains high pressures up to 10K PSI, intelligently limited to the maximum safe operating threshold of the 1\/2\" NPT threaded connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eCrossover Functionality:\u003c\/b\u003e Direct transition from Autoclave-style high-pressure rigid tubing systems to universally available 1\/2\" NPT threaded instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eAutoclave-Style HP Connection:\u003c\/b\u003e Features a standard coned and threaded interface for a highly reliable metal-to-metal seal on the 9\/16\" HP side.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eLarge-Bore 1\/2\" NPT Port:\u003c\/b\u003e Enables the secure mounting of heavy-duty pressure gauges, transmitters, and larger-volume flow components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eCold-Worked 316 SS Construction:\u003c\/b\u003e Delivers high structural integrity alongside exceptional resistance to chemical attack, rust, and sour gas (H2S).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eReduced Leak Paths:\u003c\/b\u003e A solid, single-piece machined design minimizes equipment complexity and enhances overall system safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eSpecifications \u0026amp; Technical Details\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003eStraight Crossover Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003e\u003cb data-path-to-node=\"10,2,0,0\" data-index-in-node=\"0\"\u003eEnd Connection 1\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003e9\/16\" High Pressure (HP) Male – Cone \u0026amp; Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003e\u003cb data-path-to-node=\"10,3,0,0\" data-index-in-node=\"0\"\u003eEnd Connection 2\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003e1\/2\" NPT (National Pipe Thread) Female\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003e\u003cb data-path-to-node=\"10,4,0,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003e10,000 PSI (10K MAWP) – \u003ci data-path-to-node=\"10,4,1,0\" data-index-in-node=\"24\"\u003eNPT Limited\u003c\/i\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003e\u003cb data-path-to-node=\"10,5,0,0\" data-index-in-node=\"0\"\u003eMaterial\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003eCold-Worked 316 Stainless Steel (SS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003e\u003cb data-path-to-node=\"10,6,0,0\" data-index-in-node=\"0\"\u003eSeal Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003eMetal-to-Metal (HP End) \/ Tapered Thread (NPT End)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003e\u003cb data-path-to-node=\"10,7,0,0\" data-index-in-node=\"0\"\u003eService Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003eStandard and Corrosive Service\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003e\u003cb data-path-to-node=\"10,8,0,0\" data-index-in-node=\"0\"\u003eTypical Applications\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003eGauge mounting, test panels, chemical injection skids\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003e\u003cb data-path-to-node=\"10,9,0,0\" data-index-in-node=\"0\"\u003eTesting \u0026amp; Compliance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003eStrict dimensional verification and material traceability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eApplications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003eThis 9\/16\" HP x 1\/2\" NPT female adapter is primarily utilized for stepping down from ultra-high-pressure lines to mount larger standard pressure monitoring equipment. Typical applications include installing 1\/2\" NPT analog gauges or heavy-duty electronic transmitters on hydrostatic test benches, attaching pulsation dampeners to pump discharge manifolds, and routing fluids into standard pipe-threaded distribution manifolds.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eQuality Assurance\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003eEach adapter is CNC-machined to exacting tolerances under rigorous quality control standards. The 9\/16\" HP coned seating surface undergoes strict visual and dimensional gauging to ensure flawless metal-to-metal engagement, while the NPT threads are precisely cut and gauged to prevent galling and ensure a leak-proof interference fit. All 316 SS materials are fully traceable, guaranteeing safe and reliable performance at up to 10,000 PSI.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eRequest a Quote\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e📞 +1 405 666 5011\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e📧 seo@blazess.com\u003c\/p\u003e","brand":"Blaze Sales \u0026 Service","offers":[{"title":"Default Title","offer_id":48123611939061,"sku":"90016X1002","price":40.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/5785\/1637\/files\/916HPMalex12NPTFemaleAdapter10KPSI316SSFitting.png?v=1777989726","url":"https:\/\/blazess.com\/products\/9-16-hp-male-x-1-2-npt-female-adapter-10-000-psi-stainless-steel-crossover-fitting","provider":"Blaze Sales \u0026 Service","version":"1.0","type":"link"}