{"product_id":"manual-gate-valve-2-9-16-15m-fc-style-ee-0-5-trim","title":"MANUAL GATE VALVE, 2-9\/16\", 15M,  FC-STYLE, EE-0.5 TRIM","description":"\u003cp data-start=\"1516\" data-end=\"1882\"\u003eThe Blaze Manual Gate Valve, 2-9\/16\", 15M, FC-Style, is engineered for reliable high-pressure shutoff in demanding upstream operations. Rated for 15,000 PSI and built to API 6A requirements, this valve provides dependable isolation in wellhead systems, choke and kill manifolds, frac support equipment, drilling operations, and high-pressure production applications.\u003c\/p\u003e\n\u003cp data-start=\"1884\" data-end=\"2358\"\u003eConstructed from forged alloy steel, the valve is designed for long-term performance in harsh environments involving drilling mud, hydrocarbons, cement slurry, and completion fluids. The FC-Style body supports stable gate movement, while the corrosion-resistant trim option enhances sealing durability for standard service applications. Manual handwheel operation provides direct, controlled actuation in field locations where hydraulic or electric systems are not required.\u003c\/p\u003e\n\u003cp data-start=\"2360\" data-end=\"2546\"\u003eWith a rugged build and field-serviceable design, the Blaze 2-9\/16\" 15M Manual Gate Valve delivers consistent shutoff performance and pressure control across extreme upstream conditions.\u003c\/p\u003e\n\u003chr data-start=\"2548\" data-end=\"2551\"\u003e\n\u003ch2 data-start=\"2553\" data-end=\"2578\"\u003e\u003cstrong data-start=\"2555\" data-end=\"2578\"\u003eFeatures \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2580\" data-end=\"3295\"\u003e\n\u003cli data-start=\"2580\" data-end=\"2671\"\u003e\n\u003cp data-start=\"2582\" data-end=\"2671\"\u003e\u003cstrong data-start=\"2582\" data-end=\"2603\"\u003eAPI 6A Compliant:\u003c\/strong\u003e Manufactured to recognized wellhead and tree equipment standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2672\" data-end=\"2762\"\u003e\n\u003cp data-start=\"2674\" data-end=\"2762\"\u003e\u003cstrong data-start=\"2674\" data-end=\"2702\"\u003e15,000 PSI Rating (15M):\u003c\/strong\u003e Suitable for extreme high-pressure upstream applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2763\" data-end=\"2851\"\u003e\n\u003cp data-start=\"2765\" data-end=\"2851\"\u003e\u003cstrong data-start=\"2765\" data-end=\"2783\"\u003eFC-Style Body:\u003c\/strong\u003e Supports stable gate movement and consistent sealing performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2852\" data-end=\"2939\"\u003e\n\u003cp data-start=\"2854\" data-end=\"2939\"\u003e\u003cstrong data-start=\"2854\" data-end=\"2883\"\u003eCorrosion-Resistant Trim:\u003c\/strong\u003e Designed for durability in standard oilfield service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2940\" data-end=\"3020\"\u003e\n\u003cp data-start=\"2942\" data-end=\"3020\"\u003e\u003cstrong data-start=\"2942\" data-end=\"2963\"\u003eReliable Shutoff:\u003c\/strong\u003e Provides dependable isolation for critical operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3021\" data-end=\"3113\"\u003e\n\u003cp data-start=\"3023\" data-end=\"3113\"\u003e\u003cstrong data-start=\"3023\" data-end=\"3051\"\u003eForged Alloy Steel Body:\u003c\/strong\u003e Built for strength and resistance to abrasive field fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3114\" data-end=\"3211\"\u003e\n\u003cp data-start=\"3116\" data-end=\"3211\"\u003e\u003cstrong data-start=\"3116\" data-end=\"3147\"\u003eManual Handwheel Operation:\u003c\/strong\u003e Enables precise, controlled actuation without external power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3212\" data-end=\"3295\"\u003e\n\u003cp data-start=\"3214\" data-end=\"3295\"\u003e\u003cstrong data-start=\"3214\" data-end=\"3236\"\u003eField-Serviceable:\u003c\/strong\u003e Simplifies maintenance and reduces operational downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3297\" data-end=\"3300\"\u003e\n\u003ch2 data-start=\"3302\" data-end=\"3342\"\u003e\u003cstrong data-start=\"3304\" data-end=\"3342\"\u003eSpecifications \u0026amp; Technical Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"3344\" data-end=\"3380\"\u003e\u003cstrong data-start=\"3348\" data-end=\"3380\"\u003eDetailed Specification Table\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3382\" data-end=\"4116\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3382\" data-end=\"3418\"\u003e\n\u003ctr data-start=\"3382\" data-end=\"3418\"\u003e\n\u003cth data-start=\"3382\" data-end=\"3397\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3384\" data-end=\"3396\"\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"3397\" data-end=\"3418\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3399\" data-end=\"3416\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3456\" data-end=\"4116\"\u003e\n\u003ctr data-start=\"3456\" data-end=\"3494\"\u003e\n\u003ctd data-start=\"3456\" data-end=\"3473\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3458\" data-end=\"3472\"\u003eValve Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3473\" data-end=\"3494\"\u003eManual Gate Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3495\" data-end=\"3517\"\u003e\n\u003ctd data-start=\"3495\" data-end=\"3506\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3497\" data-end=\"3505\"\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3506\" data-end=\"3517\" data-col-size=\"md\"\u003e2-9\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3518\" data-end=\"3560\"\u003e\n\u003ctd data-start=\"3518\" data-end=\"3540\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3520\" data-end=\"3539\"\u003ePressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3540\" data-end=\"3560\"\u003e15,000 PSI (15M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3561\" data-end=\"3592\"\u003e\n\u003ctd data-start=\"3561\" data-end=\"3580\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3563\" data-end=\"3579\"\u003eDesign Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3580\" data-end=\"3592\"\u003eFC-Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3593\" data-end=\"3660\"\u003e\n\u003ctd data-start=\"3593\" data-end=\"3613\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3595\" data-end=\"3612\"\u003eTrim Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3613\" data-end=\"3660\"\u003eCorrosion-Resistant Trim (Standard Service)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3661\" data-end=\"3690\"\u003e\n\u003ctd data-start=\"3661\" data-end=\"3680\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3663\" data-end=\"3679\"\u003eAPI Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3680\" data-end=\"3690\"\u003eAPI 6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3691\" data-end=\"3733\"\u003e\n\u003ctd data-start=\"3691\" data-end=\"3711\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3693\" data-end=\"3710\"\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3711\" data-end=\"3733\"\u003eForged Alloy Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3734\" data-end=\"3777\"\u003e\n\u003ctd data-start=\"3734\" data-end=\"3757\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3736\" data-end=\"3756\"\u003eOperation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3757\" data-end=\"3777\"\u003eManual Handwheel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3778\" data-end=\"3826\"\u003e\n\u003ctd data-start=\"3778\" data-end=\"3797\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3780\" data-end=\"3796\"\u003eService Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3797\" data-end=\"3826\"\u003eStandard Oilfield Service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3827\" data-end=\"3893\"\u003e\n\u003ctd data-start=\"3827\" data-end=\"3849\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3829\" data-end=\"3848\"\u003eEnd Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3849\" data-end=\"3893\" data-col-size=\"md\"\u003eFlanged (other configurations available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3894\" data-end=\"3975\"\u003e\n\u003ctd data-start=\"3894\" data-end=\"3921\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3896\" data-end=\"3920\"\u003eTypical Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3921\" data-end=\"3975\"\u003eWellhead, frac, choke \u0026amp; kill, drilling, production\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3976\" data-end=\"4032\"\u003e\n\u003ctd data-start=\"3976\" data-end=\"4001\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3978\" data-end=\"4000\"\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4001\" data-end=\"4032\"\u003eBased on selected materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4033\" data-end=\"4116\"\u003e\n\u003ctd data-start=\"4033\" data-end=\"4060\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4035\" data-end=\"4059\"\u003eTesting \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4060\" data-end=\"4116\"\u003eHydrostatic \u0026amp; functional testing per API 6A \/ API Q1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4118\" data-end=\"4121\"\u003e\n\u003ch2 data-start=\"4123\" data-end=\"4141\"\u003e\u003cstrong data-start=\"4125\" data-end=\"4141\"\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4143\" data-end=\"4482\"\u003eThis 15M manual gate valve is suitable for high-pressure upstream operations requiring reliable shutoff and mechanical isolation. Typical uses include wellhead assemblies, frac manifolds, kill lines, production flowlines, drilling choke systems, pressure-control setups, and completion operations where 15M pressure capability is required.\u003c\/p\u003e\n\u003chr data-start=\"4484\" data-end=\"4487\"\u003e\n\u003ch2 data-start=\"4489\" data-end=\"4512\"\u003e\u003cstrong data-start=\"4491\" data-end=\"4512\"\u003eQuality Assurance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4514\" data-end=\"4756\"\u003eEach valve is manufactured under API 6A and API Q1 quality systems and undergoes hydrostatic testing, functional checks, material traceability verification, and NDT inspection to ensure dependable performance in extreme pressure environments.\u003c\/p\u003e\n\u003chr data-start=\"4758\" data-end=\"4761\"\u003e\n\u003ch2 data-start=\"4763\" data-end=\"4786\"\u003e\u003cstrong data-start=\"4765\" data-end=\"4784\"\u003eRequest a Quote\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4787\" data-end=\"4828\"\u003e📞 +1 405 666 5011\u003cbr data-start=\"4805\" data-end=\"4808\"\u003e📧 \u003ca data-start=\"4811\" data-end=\"4826\" class=\"decorated-link cursor-pointer\" rel=\"noopener\"\u003eseo@blazess.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Blaze Sales \u0026 Service","offers":[{"title":"Default Title","offer_id":47304575975669,"sku":null,"price":4999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/5785\/1637\/files\/Manual_FC_GATE_VALVE-_API_6A.png?v=1772652114","url":"https:\/\/blazess.com\/products\/manual-gate-valve-2-9-16-15m-fc-style-ee-0-5-trim","provider":"Blaze Sales \u0026 Service","version":"1.0","type":"link"}