{"product_id":"2-figure-1502-female-threaded-blind-with-9-16-autoclave-tap-high-pressure-hammer-union","title":"2\" Figure 1502 Female (Threaded) Blind with 9\/16\" Autoclave Tap – High Pressure Hammer Union","description":"\u003cp data-path-to-node=\"4\"\u003eThe 2\" Figure 1502 Female (Threaded) Blind with a 9\/16\" Autoclave Tap is a highly specialized flowline component engineered for extreme-pressure environments where absolute sealing integrity is required. By combining the robust termination of a standard 15,000 PSI Figure 1502 blind with a precision-machined 9\/16\" Autoclave (cone-and-thread) port, this tapped bull plug allows for ultra-secure instrumentation access at the dead-end of a high-pressure manifold.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003eRated for a Cold Working Pressure (CWP) of 15,000 PSI, this blind is specifically designed for the severe conditions of hydraulic fracturing, well-testing, and extreme-pressure chemical injection. The integrated 9\/16\" Autoclave connection provides a superior, blowout-proof metal-to-metal seal compared to standard NPT threads. This makes it the preferred choice for critical pressure gauge mounting, transducer installation, and pressure bleed-off operations where safety and leak-prevention cannot be compromised.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003eManufactured from premium high-strength forged alloy steel, the 2\" 1502 Autoclave Tapped Female Blind ensures maximum structural integrity. Its threaded (female) hub profile is fully interchangeable with all industry-standard 2\" 1502 male union ends, providing a dependable solution for monitoring and managing extreme pressure in demanding upstream operations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eFeatures \u0026amp; Benefits\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e9\/16\" Autoclave Instrumentation Port:\u003c\/b\u003e Provides an ultra-secure, metal-to-metal sealing point for extreme-pressure gauges, sensors, or specialized valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003e15,000 PSI CWP Rating:\u003c\/b\u003e Specifically built for extreme high-pressure upstream service and stimulation applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eForged Alloy Steel Construction:\u003c\/b\u003e Premium forged materials provide maximum resistance to impact, severe vibration, and mechanical fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eStandardized Interchangeability:\u003c\/b\u003e The threaded hub design ensures a perfect fit with all standard 2\" Figure 1502 male wing nut ends.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eSuperior Leak Prevention:\u003c\/b\u003e Autoclave cone-and-thread technology eliminates the vulnerabilities of tapered pipe threads under high pulsation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eReduced Leak Paths:\u003c\/b\u003e Consolidates flowline termination and extreme-pressure instrumentation access into a single, heavy-duty fitting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eSpecifications \u0026amp; Technical Details\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003eTapped Hammer Union Blind (Plug)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003e\u003cb data-path-to-node=\"10,2,0,0\" data-index-in-node=\"0\"\u003eFigure Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003eFigure 1502\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003e\u003cb data-path-to-node=\"10,3,0,0\" data-index-in-node=\"0\"\u003ePrimary Size\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003e2\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003e\u003cb data-path-to-node=\"10,4,0,0\" data-index-in-node=\"0\"\u003eTap Size \u0026amp; Style\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003e9\/16\" Autoclave (Cone-and-Thread)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003e\u003cb data-path-to-node=\"10,5,0,0\" data-index-in-node=\"0\"\u003eConnection End\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003eFemale (Threaded Hub \/ Nut End Compatibility)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003e\u003cb data-path-to-node=\"10,6,0,0\" data-index-in-node=\"0\"\u003ePressure Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003e15,000 PSI CWP (Body Rating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003e\u003cb data-path-to-node=\"10,7,0,0\" data-index-in-node=\"0\"\u003eMaterial\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003eHigh-Strength Forged Alloy Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003e\u003cb data-path-to-node=\"10,8,0,0\" data-index-in-node=\"0\"\u003eService Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003eExtreme High-Pressure Oilfield Service\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003e\u003cb data-path-to-node=\"10,9,0,0\" data-index-in-node=\"0\"\u003eTypical Applications\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003ePrecision pressure monitoring, test manifolds, chemical injection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003e\u003cb data-path-to-node=\"10,10,0,0\" data-index-in-node=\"0\"\u003eTesting \u0026amp; Compliance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003eHydrostatic testing and material traceability to industry standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eApplications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003eThis 2\" Figure 1502 Autoclave tapped female blind is essential for extreme-pressure operations requiring both system closure and highly secure pressure diagnostics. Typical uses include capping off fracturing or well-test manifolds while providing an Autoclave port for critical transducers, acting as an extreme-pressure bleed-off point, and facilitating chemical injection into isolated flowline segments.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eQuality Assurance\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003eEach tapped blind is manufactured under rigorous quality control protocols and undergoes precise dimensional inspection and non-destructive testing (NDT) to ensure the integrity of the hammer union profile and the high-pressure cone-and-thread tap under extreme operational conditions.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eRequest a Quote\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e📞 +1 405 666 5011\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e📧 seo@blazess.com\u003c\/p\u003e","brand":"Blaze Sales \u0026 Service","offers":[{"title":"Default Title","offer_id":48055991894261,"sku":"21502-FB-90016","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/5785\/1637\/files\/2_Fig_1502_Female_Blind_with_9_16_Autoclave_Tap_15K_Union.png?v=1776867994","url":"https:\/\/blazess.com\/tr\/products\/2-figure-1502-female-threaded-blind-with-9-16-autoclave-tap-high-pressure-hammer-union","provider":"Blaze Sales \u0026 Service","version":"1.0","type":"link"}