{"product_id":"2fig-1502-9-valves-2-choke-manifold","title":"2\" FIG. 1502 - 9 Valves, 2 Choke Manifold","description":"\u003cp data-sourcepos=\"9:1-9:1068\"\u003e\u003cstrong\u003e2\" FIG. 1502 - 9 Valves, 2 Choke Manifold\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"9:1-9:1068\"\u003eIn the demanding world of oil and gas exploration and production, control over wellbore pressure is not merely a preference, but an absolute necessity. The 2\" FIG. 1502 - 9 Valves, 2 Choke Manifold, offered by Blaze Sales and Service, stands as a testament to uncompromising engineering and reliability. This robust and meticulously designed system is your frontline defense and precision tool for managing the formidable forces encountered in high-pressure oilfield environments. Built to the stringent FIG. 1502 standard, it ensures a secure, leak-proof connection capable of withstanding extreme pressures, making it indispensable for drilling, well testing, and workover operations. With its array of nine strategically placed valves and a dual-choke configuration, this manifold provides unparalleled flexibility and safety, allowing operators to precisely control flow rates and pressures, thereby safeguarding personnel, equipment, and the environment. Invest in the integrity of your operations with equipment engineered for resilience and supreme performance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONSTRUCTION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e* 2\"Fig. 1502 choke manifold Assembly.\u003cbr\u003e* Consists of two numbers of choke and nine numbers of plug valve.\u003cbr\u003e* Provision for measurement of pressure and temperature.\u003cbr\u003e* Available with skid.\u003cbr\u003e* Approximate weight is 604.5 kg.\u003c\/p\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003cdiv class=\"table-block has-export-button\"\u003e\n\u003cdiv class=\"table-content not-end-of-paragraph\"\u003e\n\u003ctable data-sourcepos=\"7:1-15:59\"\u003e\n\u003ctbody\u003e\n\u003ctr data-sourcepos=\"7:1-7:59\"\u003e\n\u003cth align=\"left\" data-sourcepos=\"7:1-7:10\"\u003eITEM NO.\u003c\/th\u003e\n\u003cth align=\"left\" data-sourcepos=\"7:12-7:46\"\u003eDESCRIPTION\u003c\/th\u003e\n\u003cth align=\"left\" data-sourcepos=\"7:48-7:57\"\u003eQUANTITY\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr data-sourcepos=\"9:1-9:59\"\u003e\n\u003ctd align=\"left\" data-sourcepos=\"9:1-9:10\"\u003e1\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"9:12-9:46\"\u003eADJUSTABLE CHOKE 2\" FIG. 1502\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"9:48-9:57\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-sourcepos=\"10:1-10:59\"\u003e\n\u003ctd align=\"left\" data-sourcepos=\"10:1-10:10\"\u003e2\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"10:12-10:46\"\u003eBLAST JOINT 2\" FIG. 1502\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"10:48-10:57\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-sourcepos=\"11:1-11:59\"\u003e\n\u003ctd align=\"left\" data-sourcepos=\"11:1-11:10\"\u003e3\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"11:12-11:46\"\u003eTEE 2\" MXMXF\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"11:48-11:57\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-sourcepos=\"12:1-12:59\"\u003e\n\u003ctd align=\"left\" data-sourcepos=\"12:1-12:10\"\u003e4\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"12:12-12:46\"\u003ePLUG VALVE 2\" FIG. 1502\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"12:48-12:57\"\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-sourcepos=\"13:1-13:59\"\u003e\n\u003ctd align=\"left\" data-sourcepos=\"13:1-13:10\"\u003e5\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"13:12-13:46\"\u003eCROSS 2\" MXFXFXF\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"13:48-13:57\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-sourcepos=\"14:1-14:59\"\u003e\n\u003ctd align=\"left\" data-sourcepos=\"14:1-14:10\"\u003e6\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"14:12-14:46\"\u003eBLIND FEMALE 2\" FIG. 1502\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"14:48-14:57\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-sourcepos=\"15:1-15:59\"\u003e\n\u003ctd align=\"left\" data-sourcepos=\"15:1-15:10\"\u003e7\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"15:12-15:46\"\u003eCROSS 2\" MXMXMXF\u003c\/td\u003e\n\u003ctd align=\"left\" data-sourcepos=\"15:48-15:57\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-sourcepos=\"11:1-11:13\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"13:1-20:0\"\u003e\n\u003cli data-sourcepos=\"13:1-13:195\"\u003e\n\u003cstrong\u003eFIG. 1502 Compliance:\u003c\/strong\u003e Designed and manufactured to meet the rigorous FIG. 1502 pressure rating, ensuring high-pressure integrity and reliability in the most challenging oilfield conditions.\u003c\/li\u003e\n\u003cli data-sourcepos=\"14:1-14:178\"\u003e\n\u003cstrong\u003eNine Valve Configuration:\u003c\/strong\u003e Equipped with nine high-quality valves, offering extensive control over flow paths, enabling bypass, isolation, and intricate pressure management.\u003c\/li\u003e\n\u003cli data-sourcepos=\"15:1-15:225\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-2\"\u003eDual Choke System:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-2 citation-end-2\"\u003e Features two choke lines (one main, one bypass\/kill line), providing redundant pressure control, allowing for continuous operation and enhanced safety during choke changes or maintenance.\u003c\/span\u003e\u003cbr\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e \u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"16:1-16:169\"\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Constructed from high-grade alloy steel, engineered to resist wear, corrosion, and erosion inherent in abrasive and corrosive oilfield fluids.\u003c\/li\u003e\n\u003cli data-sourcepos=\"17:1-17:153\"\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e Provides critical control over wellbore kicks and pressure surges, protecting drilling rigs and personnel from potential blowouts.\u003c\/li\u003e\n\u003cli data-sourcepos=\"18:1-18:171\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-1\"\u003eOptimized Flow Control:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-1 citation-end-1\"\u003e Enables precise adjustment of flow rates and wellbore pressures, crucial for well cleanup, testing, and production optimization.\u003c\/span\u003e\u003cbr\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e \u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"19:1-20:0\"\u003e\n\u003cstrong\u003eField-Proven Design:\u003c\/strong\u003e Built for durability and ease of maintenance, minimizing downtime and maximizing operational efficiency in remote and harsh environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"21:1-21:41\"\u003e\u003cstrong\u003eSpecifications and Technical Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"23:1-33:0\"\u003e\n\u003cli data-sourcepos=\"23:1-23:28\"\u003e\n\u003cstrong\u003eNominal Size:\u003c\/strong\u003e 2 inches\u003c\/li\u003e\n\u003cli data-sourcepos=\"24:1-24:102\"\u003e\n\u003cstrong\u003eEnd Connections:\u003c\/strong\u003e FIG. 1502 Hammer Union Ends (male and female) for secure and rapid connections.\u003c\/li\u003e\n\u003cli data-sourcepos=\"25:1-25:87\"\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e 15,000 PSI Working Pressure (WP) \/ 22,500 PSI Test Pressure (TP)\u003c\/li\u003e\n\u003cli data-sourcepos=\"26:1-26:107\"\u003e\n\u003cstrong\u003eNumber of Valves:\u003c\/strong\u003e 9 (typically includes gate valves for isolation, bypass, and manifold line control)\u003c\/li\u003e\n\u003cli data-sourcepos=\"27:1-27:161\"\u003e\n\u003cstrong\u003eChoke Configuration:\u003c\/strong\u003e 2 Chokes (Adjustable or Fixed, depending on customer specification - typically includes one main choke and one bypass\/kill line choke)\u003c\/li\u003e\n\u003cli data-sourcepos=\"28:1-28:133\"\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e High-strength alloy steel, heat-treated for enhanced toughness and durability (e.g., AISI 4130, 4140, or equivalent).\u003c\/li\u003e\n\u003cli data-sourcepos=\"29:1-29:93\"\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e Standard (Sweet Gas\/Oil)\u003c\/li\u003e\n\u003cli data-sourcepos=\"30:1-30:86\"\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e Suitable for a wide range of oilfield temperatures.\u003c\/li\u003e\n\u003cli data-sourcepos=\"32:1-33:0\"\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Hydrostatically tested and drift-tested to API 6A\/16C standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"34:1-34:16\"\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"36:1-36:137\"\u003eThe 2\" FIG. 1502 - 9 Valves, 2 Choke Manifold is an indispensable component in a variety of high-pressure oilfield operations, including:\u003c\/p\u003e\n\u003cul data-sourcepos=\"38:1-43:0\"\u003e\n\u003cli data-sourcepos=\"38:1-38:164\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-0\"\u003eDrilling Operations:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-0 citation-end-0\"\u003e Critical for controlling well kicks, circulating drilling mud, and maintaining back pressure on the annulus during drilling.\u003c\/span\u003e\u003cbr\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e \u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"39:1-39:148\"\u003e\n\u003cstrong\u003eWell Testing:\u003c\/strong\u003e Essential for regulating flow and pressure during well cleanup, flowback, and production testing to gather vital reservoir data.\u003c\/li\u003e\n\u003cli data-sourcepos=\"40:1-40:121\"\u003e\n\u003cstrong\u003eWorkover Operations:\u003c\/strong\u003e Used to manage wellbore pressure during well intervention, stimulation, and repair procedures.\u003c\/li\u003e\n\u003cli data-sourcepos=\"41:1-41:127\"\u003e\n\u003cstrong\u003eFracturing and Stimulation:\u003c\/strong\u003e Can be incorporated into fracturing setups to manage returns and maintain wellbore integrity.\u003c\/li\u003e\n\u003cli data-sourcepos=\"42:1-43:0\"\u003e\n\u003cstrong\u003eKill Operations:\u003c\/strong\u003e Provides a reliable system for pumping kill fluid into a well to control kicks and bring the well under control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-sourcepos=\"44:1-44:3\"\u003e\n\u003cp data-sourcepos=\"46:1-46:40\"\u003e\u003cstrong\u003eSupplied by Blaze Sales and Service.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"48:1-48:190\"\u003eFor inquiries and to learn more about how our 2\" FIG. 1502 - 9 Valves, 2 Choke Manifold can enhance your operations, please call us at \u003cstrong\u003e+1 405 666 5011\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"48:1-48:190\"\u003e\u003cstrong\u003eEmail : seo@blazess.com\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Blaze Sales \u0026 Service","offers":[{"title":"Default Title","offer_id":47110049857781,"sku":"12627","price":19800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0770\/5785\/1637\/files\/Screenshot2026-03-05011344.png?v=1772656860","url":"https:\/\/blazess.com\/ur\/products\/2fig-1502-9-valves-2-choke-manifold","provider":"Blaze Sales \u0026 Service","version":"1.0","type":"link"}